1.356,53 Excl. BTW1.356,53 Excl. BTW

2 op voorraad

APC Rack PDU APDU9981EU3, Switched, 0U, 16A, 400V, (21x) C13 & (3x) C19, IEC 309 16A 3Fase stekker

Artikelnummer: APC_APDU9981EU3 Categorie:

Beschrijving

APC Rack PDU APDU9981EU3, Switched, 0U, 16A, 400V, (21x) C13 & (3x) C19, IEC 309 16A 3Fase stekker. PDU types: Geschakeld, Rackcapaciteit: 0U, Soort: Driefasig. Aantal AC uitgangen: 24 AC-uitgang(en), Stopcontacttypes: C13 stekker, C19 stekker, Stekker: IEC 60309. Snoerlengte: 1,8 m, Certificering: CUL listed, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003,…. Nominale input voltage: 400 V, Stroom (max.): 16 A, AC-ingangsfrequentie: 50 – 60 Hz. Breedte: 55 mm, Diepte: 46 mm, Hoogte: 1792 mm

APC Next Generation Reliable Rack Power Distribution with Individual Outlet On/Off Control
From the world’s most trusted brand in PDUs now comes greater control of your rack IT equipment from the cloud to the edge with APC NetShelter 9000 Series Next Generation Rack PDUs that offer a more reliable, intelligent, and faster to deploy PDU. With Industry leading reliability, manageability, and security, APC Switched Rack PDU’s provide advanced load management plus on/off outlet level power cycling and sequencing control. Power metering provides real-time remote monitoring of connected loads with alarms to warn of potential overloads. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, and Redfish and are fully compatible with EcoStruxure IT.

Switched Power Distribution
APC Switched Rack PDUs distribute reliable rack power distribution via a single input with multiple output receptacles. Individual outlet control provides advanced load management. Real-time remote monitoring and user-defined alarms help prevent potential circuit overloads that can cause accidental power loss to critical equipment.

Power distribution
This Switched PDU from APC provides (21) C13 and (3) C19 outlets to supply power to rack equipment.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Outlet Power Sequencing
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependent on that unit will function properly.

Wireless Connectivity Compatible
Connect to this next generation PDU wirelessly with the APC USB Wi-Fi Device (sold separately, item: AP9834).

Interactive Color LCD Display and Temperature Port
Display details current, power, and voltage measurements and offers local user access. An environmental monitoring port for external temperature/humidity monitoring is available (sensor sold separately: model AP9335T or AP9335TH).

60°C (140°F) Operating Temperature
This datacenter PDU has the ability to operate in a maximum ambient air temperature of 60°C (140°F) at full load increasing reliability and availability even in today’s high-density deployments. Other models allow up to 45°C (113°F).

1% Metering Accuracy
Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy provides more precision for capacity planning and threshold alarm monitoring.

Gigabit Ethernet Connectivity
Provides Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center.

Active Power Measurements
Volts, amps, real power (kW), and energy (kWh) data is provided to support energy management. An embedded log memory to reports historic metered data.

Conveniently Power Rack-Mount Equipment
Easily mount this vertical PDU in racks or enclosures. It occupies zero U of valuable rack space, which allows space for more equipment in the rack.

Toolless Rack Mounting Capability
This vertical PDU does not require additional tools to mount into APC NetShelter Enclosures.

Package Includes
PDU, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable

Extra informatie

Gewicht 12,0000 kg
PDU types

Geschakeld

Brand

APC

State

Default

Rackcapaciteit

0U

Soort

Driefasig

Montage

Verticaal

Kleur van het product

Zwart

Aantal AC uitgangen

24 AC-uitgang(en)

Stopcontacttypes

C13 stekker, C19 stekker

Stekker

IEC 60309

Snoerlengte

1,8 m

Laad-capaciteit

11040 VA

Maximale ingang stroom per fase

16 A

Maximaal vermogen

11000 W

Gewicht

7 kg

Bedrijfstemperatuur (T-T)

-5 – 45 °C

Temperatuur bij opslag

-25 – 65 °C

Relatieve vochtigheid in bedrijf (V-V)

0 – 95 procent

Luchtvochtigheid bij opslag

5 – 95 procent

Certificering

CUL listed, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, UL listed, VDE

Gewicht verpakking

8,95 kg

Nominale input voltage

400 V

Netspanning, in bedrijf

230 V

Spanning

230 V

Maximum totaalstroomverbruik per fase

16 A

AC-ingangsfrequentie

50 – 60 Hz

Stroom (max.)

16 A

Breedte

55 mm

Diepte

46 mm

Hoogte

1792 mm

Breedte verpakking

165 mm

Diepte verpakking

114 mm

Hoogte verpakking

2002 mm

Hoogte, in bedrijf

0 – 3048 m

Hoogte bij opslag

0 – 15240 m

Beeldscherm

LCD

Aan/uitschakelaar

Ja

Doorgelust

Ja

Reset button

Ja